Compliance with health and safety legislation is a critical requirement for energy and infrastructure projects, particularly within high-risk environments such as solar plants, wind farms, battery energy storage systems (BESS), municipalities, and industrial facilities. Our GMR2.1 services provide clients with structured, legally compliant solutions that ensure electrical installations and operational practices meet the requirements of the Occupational Health and Safety Act and all relevant industry standards. We focus on risk mitigation, system safety, and regulatory alignment to support safe, reliable, and compliant operations across all project phases.

Comprehensive expertise

From energy management to renewable enegrgy infrastructure.

Regulatory Compliance

Full adherence to local and international standards

Cost Optimization

Services designed to reduce OPEX and CAPEX burdens

Performance Assurance

improved reliability, uptime, and efficiency of energy systems

Trusted EPC Partner

Supporting EPC contractors from construction through O&M

MV Cables and Fiber Installation

Test Type
Continuity Test (Quick Check)
Tool
Visual Fault Locator (VFL)
Continuity Checks
  • Inject red laser light into the fiber.
  • Check light at the far end to confirm continuity.
  • Check for light leakage along the route to detect bends or breaks.
  • Best for short distances (≤ 5 km), polarity checks, and end-to-end identification.
OTDR Wavelengths
  • 1310 nm → splice and bend-sensitive faults.
  • 1550 nm → long-distance attenuation/loss.
OTDR Procedure
  1. Select the correct wavelength.
  2. Use launch and receive cables.
  3. Set the correct range and pulse width.
  4. Run the test and save the trace.
Verification
  • Fiber length matches project drawings.
  • Event loss at connectors and splice points.